Menu
Your Cart

CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)

CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)
CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)
CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)
CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)
CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)
CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)
 
 PRODUCT DESCRIPTION

CyberPower OL6KERTHD UPS

6000VA | 6000 Watts | 220 VAC | IEC C13 x 4
                  




Force feedback

Force feedback

* Please Call for order to make sure stock are ready. *
* Images & product color may vary from actual products.*
* All Prices Exclude delivery/installation/activation fees. *

 
  PACKAGE CONTENTS

  • UPS


 ADDITIONAL INFORMATION

Warranty
- 2 Years CyberPower Warranty
- Manufactured and warranty provided by
CyberPower

 
  PRODUCT SPECIFICATIONS

Model OL6KERTHD
General Phase
Single Phase
Form Factor
Rackmount, Tower
UPS Topology
Online Double Conversion
Energy Saving Technology
Online ECO Mode Efficiency > 97%
Active PFC Compatibility
Yes
Input  Generator Compatibility
Yes
Nominal Input Voltage ( Vac )
200 ± 2%
208 ± 2%
220 ± 2%
230 ± 2%
240 ± 2%
Input Voltage Range ( Vac )
200 ~ 240
Adjustable Voltage Range ( Vac )
0~25% Load for 120 ~ 139 Vac
0~50% Load for 140 ~ 159 Vac
0~75% Load for 160 ~ 179 Vac
0~100% Load for 180 ~ 280 Vac
Input Frequency ( Hz )
50 ± 10
60 ± 10
Input Frequency Detection
Auto-sensing
Rated Input Current ( A )
32
Input Power Factor
0.99
Input Connector Type
Hardwire Terminal Block
Output  Capacity (VA)
6000
Capacity (Watts)
6000
On Battery Waveform
Pure Sine Wave
On Battery Voltage(s) ( Vac )
200 ± 2%
208 ± 2%
220 ± 2%
230 ± 2%
240 ± 2%
Output Voltage Setting
Configurable
On Battery Frequency ( Hz )
50 ± 0.5%
60 ± 0.5%
Output Frequency Setting
Configurable
Power Factor
1
ECO Mode Voltage Tolerance
± 10 %
± 15 %
Overload Protection
Internal Current Limiting, Circuit Breaker
Overload Protection (Line Mode)
105~125% Load for 1 min, 125~150% Load for 10 sec
Overload Protection (Battery Mode)
105~130% Load for 10 sec, 130~150% Load for 2 sec
Overload Protection (Bypass Mode)
Circuit Breaker
Crest Factor
3 : 1
Harmonic Distortion (Linear Load)
THD<3%
Harmonic Distortion (Non-linear Load)
THD<5%
Internal Bypass
Automatic Bypass, Manual Bypass
Outlet(s) - Total
7
Outlet Type
IEC C13 x 4  
IEC C19 x 2  
Hardwire Terminal Block x 1
Outlet(s) - Battery & Surge Protected
7
Outlet(s) - Critical Load (CL)
4
Outlet(s) - Non-Critical Load (NCL)
3
Typical Transfer Time ( ms )
0
Battery Runtime at Half Load ( min )
4.9
Runtime at Full Load ( min )
1.4
Typical Recharge Time ( Hours )
4
Start On Battery
Yes
Smart Battery Management (SBM)
Yes
Built-in Battery Management Module
Yes
User-replaceable
Yes - Qualified Personnel Only
Hot-swappable
Yes
Battery Type
Sealed Lead-acid
Replacement Battery Pack
RBP0144
RBP Quantity ( pcs )
1
Battery Quantity (Each RBP) ( pcs )
12
Battery Voltage (Each RBP) ( V )
144
Compatible Extended Battery Module (EBM)
BPE144VL2U01 (Built-in Charger)
Max. EBM Quantity ( pcs )
10
Surge Protection & Filtering  Surge Suppression ( Joules )
2430
EMI/RFI Filtration
Yes
Management & Communications LCD Panel
Yes
LCD Types
Color LCD
LCD Orientation
Rotatable LCD – Automatic, Rotatable LCD – via Setting
Tiltable LCD Panel
18°
LCD Information Display
Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
LCD Setting & Control
Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting, Language
LED Indicators Power On
HID Compliant USB Port(s)
1
Emergency Power Off (EPO) Port
Yes
Audible Alarms
Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
Management Cable ( pcs )
USB Cable x1, Serial Cable x1
Power Management Software
PowerPanel Business (Recommended)
SNMP/HTTP Remote Monitoring
Yes - RMCARD205 included
Physical  Enclosure Construction
Metal
Color
Black
Rackmount Rail
Yes
Rackmount Ears
Yes
High Density Design
Yes
Physical Size - UPS Module  Dimensions (WxHxD) (in.)
17 x 3.4 x 28.3
Dimensions (WxHxD) (mm.)
433 x 86.5 x 720
Rack-mounted Dimensions (WxHxD) (in.)
17 x 3.4 x 27 *Without the dimension of front panel
Rack-mounted Dimensions (WxHxD) (mm.)
433 x 86.5 x 685 *Without the dimension of front panel
Weight (lbs.)
92.4
Weight (kg.)
42
Environmental  Operating Temperature (°F)
32 ~ 104
Operating Temperature (°C)
0 ~ 40
Operating Relative Humidity (Non-condensing) ( % )
0 ~ 90
Operating Elevation ( feet/meters )
0-9,843 feet (0-3,000 meters)
Storage Temperature (°F)
23 ~ 113
Storage Temperature (°C)
-5 ~ 45
Storage Relative Humidity (Non-condensing) ( % )
0 ~ 95
Storage Elevation ( feet/meters )
0-14,764 feet (0-4,500 meters)
Online Thermal Dissipation ( BTU/hr )
1613
Audible Noise at 1.0M from Surface of Unit
43~66 dBA (0~100 % load)
Certifications  Certifications
CE, EAC, RCM
RoHS
Yes
* Prices, Features, Package Content and Specifications are subject to change without prior notification. *

CyberPower OL6KERTHD UPS (6000VA, 6000 Watts, 220 VAC, IEC C13 x 4)
AVR / UPS Specifications
AVR / UPS Backup Time -
AVR / UPS Capacity 6000VA
AVR / UPS Output 6000VAC
AVR / UPS Protection
AVR / UPS Protection Line-interactive
AVR / UPS Dimensions
AVR / UPS Dimension 600 x 335 x 1100
AVR / UPS Weight 52.1kg

Write a review

Note: HTML is not translated!
Bad Good
  • Model: OL6KERTHD
  • SKU: OL6KERTHD
0 units sold
RM13,799.00
Ex Tax: RM13,799.00